The number of turns of the actual motor is recorded by EE-SX 670P (PNP type photoelectric switch) photoelectric. The system records the actual pulse number of the encoder fed back every turn. When the friction wheel wears seriously, the actual number of pulses per revolution changes. The amount of change is judged in advance.
Parameter Description Remark
F1-25 Motor Type 1:Synchronous motor
F1-00 Encoder Type 2:ABZ Encoder
F1-01 Motor Rated Power
According to nameplate
♦F1-02 Motor Ralted Voltage
♦F1-03 Motor Ralted Current
♦F1-04 Motor Ralted Frequency
♦F1-05 Motor Rated Speed
♦F0-01 Command Source Selection 1:Distance Control
♦F1-11 Auto-Turning 1:with-Load auto-turning